Aisonic C Seperated Ultrasonic Liquid Level Meter



 
  • Measure range: 0-15m(optional)
  • Blind zone: 0.3m
  • Accuracy: ±0.3%FS,±0.5%FS
  • Power supply: 100-240 VAC,18-28 VDC
Availability:
Quantity:
facebook sharing button
twitter sharing button
line sharing button
linkedin sharing button
pinterest sharing button
sharethis sharing button
Principles


Split ultrasonic liquid level Meter /level gauge is to measure the time required for the whole process of an ultrasonic pulse from sending out to returning. Ultrasonic level meter is installed vertically on the surface of the liquid, it sends out an ultrasonic pulse to the liquid surface, after a period of time, the sensor of the ultrasonic level meter receives the signal reflected back from the liquid surface, and according to the difference in the time between the ultrasonic level meter sending out and receiving ultrasonic waves, the distance from the liquid surface to the sensor is calculated.

Ultrasonic level meter (measuring material level, liquid level), is a non-contact, highly reliable, cost-effective, easy to install and maintain the level measurement instrument. It does not have to contact the medium to meet most of the level measurement requirements, can be widely used in a variety of liquid and solid material height measurement, especially for environmental protection industry, sewage treatment site, etc..

Specification

Model Number Aisonic C
Structure Type Remote Type
Measuring Range 5m, 10m, 15m, 20m, 30m, 40m, 50m, 60m, 70m
Process Temperature -20℃ ~ +80℃
Process Pressure 0~3bar
Process Connection Thread, Flange Connection
Measurement Accuracy 0.5%-1.0%
Resolution 3mm or 0.1%
Power supply

Standard configuration: 220V AC+15%  50Hz

Optional: 24VDC 120mA

Customized: 12VDC or battery powered

Current Output 4~20 mA
Relay Output

2 groups for single channel and 4 groups for double channels (optional)

AC 250V/ 8A or DC 30V/ 5A, state programmable

Host Shell Material ABS
Sensor Housing Material ABS、PVDF、PTFE
Communication RS485, RS232 communication output is optional
Blind Zone According to the range
Ambient Temperature -20℃~+60℃
Cable Length 10 ~ 100m
Protection Grades IP65(Sensor IP68)
未标题-2
Features


  •  Suitable for non-contact measurement of liquid, slurry, sludge and other medium.

  • Maximum measuring range up to 50 meters.

  • Customer-friendly menu for quick and easy commissioning.

  • 4-20mA current output, Modbus485 communication optional.

  • Provides an alarm current output to prevent the level from entering the blind spot or exceeding the range.

  • 4~20mA analog output, optional alarm control, RS485/RS232 communication.

  • Distance measurement and level measurement can be selected.

  • Response speed can be selected from slow, medium and fast.

  • Safety level can be selected from four items: hold, minimum, maximum, and set value.

  • Upper and lower limit nodes can be set arbitrarily and online output adjustment with on-site display.

  • Display echo curve: real-time monitoring of echo energy intensity, convenient for on-site debugging.

  • Automatic temperature compensation: according to the temperature of the sound speed compensation to improve the accuracy of measurement