APT16 pH/ORP Transmitter with RS485 and Pulse output
The ARTang APT16 is an advanced panel-mount pH/ORP controller designed for industrial monitoring and automation systems.
It provides a 4–20 mA analog output, RS485 communication, one programmable relay and an optically isolated open-collector pulse output. Automatic or manual pH temperature compensation supports applications with changing process temperatures.
- pH measurement range: 0.00–14.00 pH
- ORP measurement range: −2000 to +2000 mV
- Automatic or manual pH temperature compensation
- 4–20 mA analog output
- RS485 communication
- Programmable single-relay output
Product Description
The APT16 pH/ORP transmitter and controller is designed for water-treatment systems, chemical-dosing equipment, analytical panels and OEM machinery that require multiple methods of measurement transmission and process integration.
Measurement data can be transmitted through the 4–20 mA output or RS485 interface. A programmable relay can provide an alarm or control signal, while the optically isolated open-collector pulse output supports connection to compatible pulse-input equipment.
With a compact 96 × 96 × 46 mm housing and 92 × 92 mm panel cutout, the APT16 is suitable for both new control panels and equipment-upgrade projects.
Technical Specifications
|
Parameter |
Specification |
|---|---|
|
Product model |
APT16 |
|
Product type |
Panel-mount pH/ORP transmitter and controller |
|
pH measurement range |
0.00~14.00 pH |
|
ORP measurement range |
−2000 to +2000 mV |
|
pH temperature compensation |
Automatic or manual |
|
Measured-medium temperature |
−25 to 125°C, subject to electrode and process conditions |
|
pH calibration |
Three-point calibration: pH 4.00, 6.86 and 9.18 |
|
Output |
4–20 mA,One programmable relay output,Optically isolated open-collector signal |
|
Communication |
RS485 |
|
Power supply |
24 VDC |
|
Housing dimensions |
96 × 96 × 46 mm |
|
Required panel cutout |
92 × 92 mm |
|
Mounting method |
Panel mount |
Key Features
RS485 Digital Communication
Optically Isolated Pulse Output
Automatic or Manual Temperature Compensation
Wide Measured-Medium Temperature Range
The specified measured-medium temperature range is −25 to 125°C.
4–20 mA Analog Output
Programmable Relay Output
Compact Panel-Mount Design
Typical Applications
Water and Wastewater Treatment
- Municipal water-treatment systems
- Municipal and industrial wastewater treatment
- Neutralization processes
- Effluent pH monitoring
- Water-reuse systems
- Coagulation and chemical-dosing systems
- Packaged water-treatment equipment
Acid and Alkali Dosing
- Acid dosing
- Alkali dosing
- Neutralization control
- pH adjustment skids
- Batch treatment tanks
- Chemical-treatment equipment
- Industrial wastewater pH control
ORP and Redox Monitoring
- Oxidation process monitoring
- Reduction process monitoring
- Chlorination control
- Dechlorination systems
- Ozone-treatment systems
- Chemical oxidation
- Metal-treatment processes
- Selected electroplating applications
Industrial Process Water
- Cooling-water treatment
- Circulating-water systems
- Process-water monitoring
- Industrial rinse water
- Water-treatment chemical control
- Water-reuse systems
- Industrial utility water
OEM Equipment and Automation Panels
- Chemical-dosing skids
- Water-quality monitoring panels
- Packaged wastewater-treatment systems
- Filtration and pretreatment equipment
- Industrial control cabinets
- PLC-based analytical systems
- OEM pH/ORP monitoring equipment
FAQ
The APT16 should be treated as a single-channel controller configured for either pH or ORP according to the connected electrode.
Yes. RS485 communication is specified with transmission rates of:
- 4800 baud
- 9600 baud
- 19200 baud
The communication protocol and register map must be confirmed before system integration.
It provides an optically isolated open-collector pulse output with a maximum rate of 400 pulses per minute.
The output voltage, current, pulse scaling and available programmable functions must be confirmed before connection.
It may be connected to a compatible pulse-input dosing pump or controller if:
- The electrical input is compatible with an open-collector signal
- The pulse frequency is within the supported range
- The required pulse function and scaling are available
- The output voltage and current remain within specification
Confirm these requirements before using the pulse output for dosing control.
The controller and electrode should be specified separately unless the quotation states that they are supplied as a complete set.
Electrode selection depends on the liquid, temperature, pressure, contamination, mounting and temperature-compensation requirements.
The specified three-point calibration buffers are:
- pH 4.00
- pH 6.86
- pH 9.18
The APT16 requires a 92 × 92 mm panel opening.
Its external dimensions are 96 × 96 × 46 mm. Reserve adequate rear space for analog, relay, pulse and RS485 wiring.
Request a Quote and System Integration Support
Need the APT16 controller only or a complete pH/ORP measurement system?
Send us your measured liquid, pH or ORP range, process temperature, electrode requirements, output functions, RS485 protocol requirements and host-system information.
ARTang will help confirm the controller, electrode and system interface before quotation.
Factory Strength & Quality Assurance
ARTang supports industrial measurement projects with in-house production, strict calibration, certified quality control, and global exhibition experience.
Factory Production
In-house production and assembly for stable product quality and reliable delivery.

CNC Machining Equipment

Product Assembly

CNC Machining

Welding Process

warehouse

Technical Support Department
Certified Quality
Product certificates and quality control systems support reliable industrial measurement applications.

CE

ISO

3-A

NEPSI
Exhibition Experience
ARTang meets customers and distributors at industry exhibitions to better understand project needs and market requirements.