AOT115 Dissolved Oxygen Transmitter with Large LCD

The ARTang AOT115 is a panel-mount dissolved oxygen transmitter for local measurement display and signal transmission in water quality analysis. Its large backlit dot-matrix LCD shows dissolved oxygen and temperature, with an English-language interface and front-panel keys.

The instrument provides a 4–20 mA output and two SPST relay outputs. Optional RS485 communication supports Modbus RTU for integration with a compatible monitoring system.

  • Dissolved oxygen ranges: 0.0–40.00 mg/L and 0.0–400.0%
  • Resolution: 0.01 mg/L and 0.1%
  • Automatic or manual temperature compensation
  • Salinity and pressure compensation
  • 4–20 mA output and two SPST relay outputs
  • Optional RS485 communication with Modbus RTU
  • 100–240 VAC or 24 VDC supply options
  • 144 × 144 mm front panel; 138 × 138 mm panel cutout

    Product Description

    The AOT115 connects to a compatible dissolved oxygen electrode and an NTC22K temperature sensor. Operators can view measurements and set instrument parameters using the front-panel interface, while the 4–20 mA output provides a signal for a compatible PLC, recorder or monitoring input.

    Automatic and manual temperature compensation are supported during measurement and calibration. The actual measuring-system range and process limits depend on the connected electrode as well as the transmitter.

    AOT115 dissolved oxygen transmitter front dimensions showing 144 × 144 mm panel size.
    AOT115 dissolved oxygen transmitter side dimensions showing 25 mm front panel depth and 90 mm housing depth.
    AOT115 dissolved oxygen transmitter bottom dimensions showing 144 mm width and 115 mm depth.

    Technical Specifications

    Parameter

    Specification

    Model

    AOT115

    Measured variables

    Dissolved oxygen and temperature

    Dissolved oxygen range

    0.0–40.00 mg/L; 0.0–400.0%

    Dissolved oxygen resolution

    0.01 mg/L; 0.1%

    Dissolved oxygen accuracy

    ±2% FS

    Temperature input

    NTC22K

    Temperature resolution

    0.1 °C

    Temperature accuracy

    ±0.2 °C

    Temperature compensation

    −10.0 to 130.0 °C; automatic or manual

    Salinity compensation

    0.0–40.0 ppt; 0.1 ppt resolution

    Pressure compensation

    600–2000 mbar; 1 mbar resolution

    Outputs & Power Supply

    Parameter

    Specification

    Analog output

    4–20 mA

    Communication

    RS485 with Modbus RTU, optional

    Relay outputs

    2 SPST relays

    Relay contact rating

    5 A at 250 VAC; 5 A at 30 VDC

    Power supply options

    100–240 VAC or 24 VDC

    Environmental & Installation

    Parameter

    Specification

    Ambient operating temperature

    0–70 °C

    Storage temperature

    −20 to 70 °C

    Operating humidity

    <90%

    Protection rating

    IP65

    Mounting method

    Panel mount

    Front panel dimensions

    144 × 144 mm (H × W)

    Panel cutout

    138 × 138 mm

    Weight

    0.85 kg

    Product Features

    Large Backlit Display

    Read dissolved oxygen and temperature locally and access settings through the English-language interface and front-panel keys.

    Analog and Optional Digital Communication

    Use the 4–20 mA output with a compatible analog input. Specify the RS485 option when Modbus RTU communication is required.

    Temperature Salinity and Pressure Compensation

    Configure temperature compensation in automatic or manual mode and use the specified salinity and pressure compensation functions for the measurement conditions.

    Typical Applications

    The AOT115 is intended for dissolved oxygen and temperature measurement in water quality analysis. Applications include:

    • Waterworks and aquaculture
    • Biological fermentation
    • Metallurgical and chemical processes
    • Pharmaceutical production

    Select the connected electrode for the process liquid, measuring range, temperature, pressure and installation. The transmitter’s compensation range and enclosure rating do not replace the electrode’s process specifications.

    Frequently Asked Questions

    Does the AOT115 measure dissolved oxygen and temperature?

    Yes. Dissolved oxygen and temperature are the specified measured variables. The temperature input is NTC22K, with 0.1 °C resolution and ±0.2 °C temperature measurement accuracy.

    Is RS485 communication standard?

    RS485 communication with Modbus RTU is optional. Specify this option when it is required for the monitoring system.

    Does the AOT115 support automatic temperature compensation?

    Yes. Automatic and manual temperature compensation are supported during measurement and calibration. If the temperature probe is damaged, compensation can be switched to manual mode.

    Can the temperature compensation range be used as the electrode temperature rating?

    No. The −10.0 to 130.0 °C range applies to the transmitter’s compensation function. The connected electrode must be selected against its own temperature and process limits. The AOS115 lists a temperature measuring range of 0.0–60.0 °C.

    Does an AOT115 and AOS115 system cover 0–40 mg/L?

    The AOT115 instrument range extends to 40.00 mg/L, but the AOS115 electrode is specified to 20.00 mg/L. A combined system must stay within the selected electrode’s specified range, and electrical compatibility must be checked before pairing.

    What panel opening and power supply are required?

    The panel cutout is 138 × 138 mm and the front panel measures 144 × 144 mm. Supply options are 100–240 VAC or 24 VDC; specify the required version when ordering.

    Discuss Your Dissolved Oxygen Measurement Requirements

    Send ARTang your dissolved oxygen range, process liquid, temperature, pressure, existing electrode details, power supply and output requirements. Include whether RS485 communication is required so the transmitter configuration and electrode pairing can be reviewed.

    Factory Strength & Quality Assurance

    ARTang supports industrial measurement projects with in-house production, strict calibration, certified quality control, and global exhibition experience.

    Factory Production

    In-house production and assembly for stable product quality and reliable delivery.

    Worker operating production equipment for instruments and meters

    CNC Machining Equipment

    ARTang worker operating production instruments and equipment

    Product Assembly

    CNC Machining

    Welding Process

    artang warehouse

    warehouse

    Technical Support Department

    Certified Quality

    Product certificates and quality control systems support reliable industrial measurement applications.

    CE certificate for electromagnetic flowmeter

    CE

    ISO 9001 quality management system certificate

    ISO

    3-A sanitary certificate for electromagnetic flowmeter

    3-A

    NEPSI explosion protection certificate for integral magnetic flowmeter

    NEPSI

    Exhibition Experience

    ARTang meets customers and distributors at industry exhibitions to better understand project needs and market requirements.

    ARTang at an industrial instrumentation exhibition, showcasing flow meters and pressure transmitters for process automation applications