AOS115 Membrane Dissolved Oxygen Electrode for Water and Aquaculture

The ARTang AOS115 is a membrane-covered dissolved oxygen electrode for water treatment, aquaculture and environmental monitoring. It measures dissolved oxygen from 0.00 to 20.00 mg/L and is available in flow-through and immersion designs.

Six configurations combine different housing materials, process connections and membrane types, allowing the electrode to be selected for the installation.

  • Dissolved oxygen measuring range: 0.00–20.00 mg/L
  • Measurement accuracy: ±2% FS
  • Temperature measuring range: 0.0–60.0 °C
  • Flow-through and immersion configurations
  • IP68 protection; pressure rating: 0–2 bar
  • NTC22K temperature sensor; Pt100, Pt1000 and NTC2.252K optional
  • 5 m standard cable; custom lengths available

    Product Description

    The AOS115 measures dissolved oxygen using a membrane-covered electrode with a specified polarization voltage of 675 mV. It requires a compatible dissolved oxygen transmitter for measurement and indication. Select the temperature element and electrical connection to match the transmitter input.

    The electrode requires a minimum medium flow velocity of 0.02 m/s. Routine care includes calibration, electrolyte replacement or replenishment, and membrane cap replacement.

    Technical Specifications

    Parameter

    Specification

    Model

    AOS115

    Measurement principle

    Membrane-based

    Dissolved oxygen range

    0.00–20.00 mg/L (ppm)

    Measurement accuracy

    ±2% FS

    Response time

    90% of the final value within 90 s

    Temperature range

    0.0–60.0 °C

    Polarization voltage

    675 mV

    Pressure rating

    0–2 bar

    Minimum flow velocity

    0.02 m/s

    Storage temperature

    −20.0 to 60.0 °C

    Temperature Sensor

    NTC22K; Pt100, Pt1000 and NTC2.252K optional

    Electrical Connection

    Pin-type or BNC

    Cable Length

    5 m standard; custom lengths available

    Protection rating

    IP68

    Sensor Construction

    The configurations below correspond to Figures 1–6 in the AOS115 Technical Information. Housing materials and membrane types depend on the selected configuration.

    AOS115 ABS flow-through dissolved oxygen electrode with M39×1.5 connection
    Figure 1 ABS Flow-through Design (M39×1.5)
    AOS115 flow-through dissolved oxygen electrode with M28×1.5 connection
    Figure 2 Metal Flow-through Design (M28×1.5)
    AOS115 flow-through dissolved oxygen electrode with G3/4 connection
    Figure 3 Flow-through Design (G3/4)
    AOS115 immersion dissolved oxygen electrode with G3/4 connection
    Figure 4 Immersion Design (G3/4)
    AOS115 large-diameter immersion dissolved oxygen electrode with G3/4 and G1 connections
    Figure 5 Large-Diameter Immersion Design (G3/4, G1)
    AOS115 slim-shaft dissolved oxygen electrode with PG13.5 connection
    Figure 6 Slim Flow-through Design (PG13.5)

    Figure

    Mounting method

    Housing material

    Process connection

    Membrane type

    1

    Flow-through

    ABS

    M39×1.5

    Oxygen-sensitive membrane

    2

    Flow-through

    PC + stainless steel

    M28×1.5

    Oxygen-sensitive membrane

    3

    Flow-through

    PC + stainless steel

    G3/4

    Oxygen-sensitive membrane

    4

    Immersion

    PC + stainless steel

    G3/4

    Reinforced oxygen membrane

    5

    Immersion

    POM + stainless steel

    G3/4, G1

    Reinforced oxygen membrane

    6

    Flow-through

    PC + stainless steel

    PG13.5

    Oxygen-sensitive membrane

    Product Features

    Flow-through & Immersion Designs

    Available in different mounting configurations to suit installation requirements.

    Six Configuration Options

    Multiple housing materials, process connections, and membrane types for different applications.

    Selectable Temperature Sensors

    NTC22K standard, with Pt100, Pt1000, and NTC2.252K options.

    Replaceable Membrane & Electrolyte

    Replaceable components support routine maintenance and continued operation.

    Typical Applications

    Typical applications include drinking water treatment, sewage treatment, industrial wastewater treatment, aquaculture and environmental monitoring.

    Select the electrode configuration against the medium, pressure, temperature requirements and mounting arrangement. Maintain the specified minimum flow velocity at the sensor.

    Calibration and Maintenance

    The AOS115 supports zero-oxygen and saturation calibration. Recommended maintenance intervals include:

    • Calibration: Once per month.

    • Electrolyte: Replace or replenish every 3–6 months.

    • Membrane Cap: Replace every 6–12 months.

    Maintenance intervals may vary depending on operating conditions.

    Frequently Asked Questions

    Is the AOS115 an optical dissolved oxygen sensor?

    No. The AOS115 uses a membrane-based electrode. Its specifications include a 675 mV polarization voltage and periodic electrolyte and membrane cap maintenance.

    Which process connections are available?

    Available configurations include M39×1.5, M28×1.5, G3/4, G3/4 with G1, and PG13.5 connections. Each connection is associated with a specific mounting method, housing material and membrane type; refer to the configuration table.

    Does the electrode need flow across the membrane?

    Yes. The specified minimum medium flow velocity is 0.02 m/s. The flow requirement also applies when selecting an immersion installation.

    Which temperature element should I select?

    The temperature element must match the dissolved oxygen transmitter input. The AOS115 lists NTC22K, with Pt100, Pt1000 and NTC2.252K available as options. The AOT115 specifies an NTC22K temperature input.

    Can the AOS115 measure 40 mg/L when connected to the AOT115?

    No. The AOS115 electrode is specified for 0.00–20.00 mg/L. The AOT115 transmitter’s wider instrument range does not extend the electrode range. Confirm the electrode signal, polarization requirements, temperature element and wiring when specifying the measurement system.

    Request Electrode Selection Support

    Send ARTang your process liquid, dissolved oxygen range, temperature, pressure, flow conditions, mounting method and required cable length. If you already have a transmitter, include its model and temperature input specification so the electrode configuration can be reviewed.

    Factory Strength & Quality Assurance

    ARTang supports industrial measurement projects with in-house production, strict calibration, certified quality control, and global exhibition experience.

    Factory Production

    In-house production and assembly for stable product quality and reliable delivery.

    Worker operating production equipment for instruments and meters

    CNC Machining Equipment

    ARTang worker operating production instruments and equipment

    Product Assembly

    CNC Machining

    Welding Process

    artang warehouse

    warehouse

    Technical Support Department

    Certified Quality

    Product certificates and quality control systems support reliable industrial measurement applications.

    CE certificate for electromagnetic flowmeter

    CE

    ISO 9001 quality management system certificate

    ISO

    3-A sanitary certificate for electromagnetic flowmeter

    3-A

    NEPSI explosion protection certificate for integral magnetic flowmeter

    NEPSI