Aisonic C Split Type Ultrasonic Level Meter
Measure range: 0-15m(optional)
Blind zone: 0.3m
Accuracy: ±0.3%FS,±0.5%FS
Power supply: 100-240 VAC,18-28 VDC
Product Description
Split ultrasonic liquid level Meter /level gauge is to measure the time required for the whole process of an ultrasonic pulse from sending out to returning. Ultrasonic level meter is installed vertically on the surface of the liquid, it sends out an ultrasonic pulse to the liquid surface, after a period of time, the sensor of the ultrasonic level meter receives the signal reflected back from the liquid surface, and according to the difference in the time between the ultrasonic level meter sending out and receiving ultrasonic waves, the distance from the liquid surface to the sensor is calculated.
Ultrasonic level meter (measuring material level, liquid level), is a non-contact, highly reliable, cost-effective, easy to install and maintain the level measurement instrument. It does not have to contact the medium to meet most of the level measurement requirements, can be widely used in a variety of liquid and solid material height measurement, especially for environmental protection industry, sewage treatment site, etc..
Specification
|
Parameter |
Specification |
|---|---|
|
Model number |
Aisonic C |
|
Structure type |
remote type |
|
Measuring range |
5m, 10m, 15m, 20m, 30m, 40m, 50m, 60m, 70m |
|
Process temperature |
-20℃ ~ +80℃ |
|
Process pressure |
0~3bar |
|
Process connection |
Thread, Flange Connection |
|
Measurement accuracy |
0.5%-1.0% |
|
Resolution |
3mm or 0.1% |
|
Power supply |
Standard configuration: 220V AC+15% 50Hz |
|
Current output |
4~20 mA |
|
Relay output |
2 groups for single channel and 4 groups for double channels (optional) |
|
Host shell material |
ABS |
|
Sensor housing material |
ABS、PVDF、PTFE |
|
Communication |
RS485, RS232 communication output is optional |
|
Blind Zone |
According to the range |
|
Ambient Temperature |
-20℃~+60℃ |
|
Cable Length |
10 ~ 100m |
|
Protection Grades |
IP65(Sensor IP68) |
Features
Suitable for non-contact measurement of liquid, slurry, sludge and other medium.
Maximum measuring range up to 50 meters.
Customer-friendly menu for quick and easy commissioning.
4-20mA current output, Modbus485 communication optional.
Provides an alarm current output to prevent the level from entering the blind spot or exceeding the range.
4~20mA analog output, optional alarm control, RS485/RS232 communication.
Distance measurement and level measurement can be selected.
Response speed can be selected from slow, medium and fast.
Safety level can be selected from four items: hold, minimum, maximum, and set value.
Upper and lower limit nodes can be set arbitrarily and online output adjustment with on-site display.
Display echo curve: real-time monitoring of echo energy intensity, convenient for on-site debugging.
Automatic temperature compensation: according to the temperature of the sound speed compensation to improve the accuracy of measurement
Factory Strength & Quality Assurance
ARTang supports industrial measurement projects with in-house production, strict calibration, certified quality control, and global exhibition experience.
Factory Production
In-house production and assembly for stable product quality and reliable delivery.

CNC Machining Equipment

Product Assembly

CNC Machining

Welding Process

warehouse

Technical Support Department
Certified Quality
Product certificates and quality control systems support reliable industrial measurement applications.

CE

ISO

3-A

NEPSI
Exhibition Experience
ARTang meets customers and distributors at industry exhibitions to better understand project needs and market requirements.