Aimag H All-Stainless-Steel Sanitary Electromagnetic Flow Meter
The Aimag H is an upgraded 3-A certified sanitary electromagnetic flow meter designed for conductive liquids in hygienic production processes. It combines an all-stainless-steel housing with a compact and lightweight converter, making it well suited for food, beverage, dairy, brewing, pharmaceutical, and other hygienic applications.
Nominal Diameter: DN6–DN150
Accuracy: ±0.5%; optional ±0.2%
Housing Material: All-stainless-steel construction
Process Temperature: −40°C to 150°C
Wetted Surface Roughness: ≤0.4 µm
Hygienic Connections: Sanitary clamp, weld, and threaded connections
Certifications: 3-A, CE, and EAC
Product Description
The Aimag H sanitary electromagnetic flow meter is designed for volumetric flow measurement of conductive liquids in food, beverage, dairy, brewing, and pharmaceutical processes.
It combines a PFA liner, hygienic process connections, and wetted surfaces with a surface roughness of Ra ≤0.4 µm. The all-stainless-steel version retains the established advantages of the Aimag H sanitary platform while introducing a smaller and lighter converter, optional M12 plug-in connections, and a simplified electronic architecture.
These features make the Aimag H well suited for production lines, batching and filling systems, process skids, and CIP/SIP applications requiring hygienic construction, compact installation, and convenient operation.
Specification
|
Parameter |
Specification |
|---|---|
|
Model |
Aimag H |
|
Product type |
Sanitary Electromagnetic Flow Meter |
|
Nominal diameter |
DN6 ~ DN150 |
|
Accuracy |
±0.5%; optional ±0.2% |
|
Converter housing |
All-stainless-steel housing |
|
Liner material |
PFA |
|
Electrode material |
316L; Hastelloy B; Hastelloy C; Platinum; Tantalum; Titanium |
|
Seal Materials |
EPDM,FKM |
|
Hygienic connections |
Tri-Clamp and other sanitary clamp connections, weld, or thread |
|
Wetted surface roughness |
Ra ≤0.4 µm |
|
Process temperature |
-40℃~150℃ |
|
Ambient temperature |
-20℃~60℃, with display |
|
Wiring options |
M12 4-pin connectors or internal terminal wiring |
|
Measuring range |
0.1m/s~10m/s |
|
Minimum conductivity |
≥5μS/cm |
|
Output signal |
4~20mA / Frequency / Pulse |
|
Communication |
Modbus RS485 |
|
Certification |
3-A, CE |
Product Feature
3-A Certified Sanitary Design
3-A certified hygienic construction supports beverage, dairy, wine, and other food-grade production lines.
High-Temperature PFA Liner
The PFA liner supports process temperatures up to 150°C and repeated CIP and SIP cleaning cycles.
Smaller and Lighter Converter
The converter is approximately 30–50% the volume of conventional designs, reducing the overall meter weight while giving the instrument a more compact and refined appearance.
All-Stainless-Steel Housing
The all-stainless-steel construction provides a clean, refined appearance and is well suited to hygienic applications in food and beverage processing.
Ra ≤0.4 µm Wetted Surfaces
Wetted surfaces with a roughness of Ra ≤0.4 µm exceed typical 3-A surface-finish requirements, helping reduce residue buildup and support effective cleaning.
Optional M12 Plug-In Connections
Optional M12 4-pin connectors enable wiring and cable replacement without opening the converter enclosure.
Supported Conditions and Functions

Supports stable operation in outdoor and industrial environments.

Supports reliable operation in industrial environments with electromagnetic interference.
Typical Applications
- Beverage production, blending, and filling lines
- Milk and dairy processing
- Brewing and wine production
- Pharmaceutical and other hygienic process systems
- CIP/SIP supply, return, and circulation lines
- Sanitary process water and cleaning-water systems
- OEM skids and packaged processing equipment

ARTang and Endress+Hauser instruments operating on the same CIP process line.

ARTang electromagnetic flow meter in a shared process application.

ARTang flow meter in a CIP line with Endress+Hauser instruments.

ARTang and KROHNE instruments used in the same blending water process.

Dairy Production

CIP Cleaning System

Beverage

Beer
flowmeter calibration equipment
Each electromagnetic flow meter is calibrated before shipment to verify its measurement accuracy and stability. Our calibration process includes standard meter method and weighing method calibration to ensure reliable performance under real working conditions.

Standard Meter Method Calibration
Accuracy is verified by comparing the electromagnetic flow meter with a certified standard meter.

Weighing Method Calibration
Flow accuracy is checked by measuring the collected liquid weight over a set time.
Related Articles
Electromagnetic Flow Meters in Brewery CIP Systems: Accurate Flow Measurement for Hygienic Cleaning Processes
How to Evaluate the Quality of a Food-Grade Electromagnetic Flowmeter: 8 Key Design Details
How to Choose the Right Electromagnetic Flowmeter for the Food Industry
Factory Strength & Quality Assurance
ARTang supports industrial measurement projects with in-house production, strict calibration, certified quality control, and global exhibition experience.
Factory Production
In-house production and assembly for stable product quality and reliable delivery.

CNC Machining Equipment

Product Assembly

CNC Machining

Welding Process

warehouse

Technical Support Department
Certified Quality
Product certificates and quality control systems support reliable industrial measurement applications.

CE

ISO

3-A

NEPSI
Exhibition Experience
ARTang meets customers and distributors at industry exhibitions to better understand project needs and market requirements.