Aimag H All-Stainless-Steel Sanitary Electromagnetic Flow Meter

The Aimag H is an upgraded 3-A certified sanitary electromagnetic flow meter designed for conductive liquids in hygienic production processes. It combines an all-stainless-steel housing with a compact and lightweight converter, making it well suited for food, beverage, dairy, brewing, pharmaceutical, and other hygienic applications.

Nominal Diameter: DN6–DN150

Accuracy: ±0.5%; optional ±0.2%

Housing Material: All-stainless-steel construction

Process Temperature: −40°C to 150°C

Wetted Surface Roughness: ≤0.4 µm

Hygienic Connections: Sanitary clamp, weld, and threaded connections

Certifications: 3-A, CE, and EAC

    Product Description

    The Aimag H sanitary electromagnetic flow meter is designed for volumetric flow measurement of conductive liquids in food, beverage, dairy, brewing, and pharmaceutical processes.

    It combines a PFA liner, hygienic process connections, and wetted surfaces with a surface roughness of Ra ≤0.4 µm. The all-stainless-steel version retains the established advantages of the Aimag H sanitary platform while introducing a smaller and lighter converter, optional M12 plug-in connections, and a simplified electronic architecture.

    These features make the Aimag H well suited for production lines, batching and filling systems, process skids, and CIP/SIP applications requiring hygienic construction, compact installation, and convenient operation.

    Specification

    Parameter

    Specification

    Model

    Aimag H

    Product type

    Sanitary Electromagnetic Flow Meter

    Nominal diameter

    DN6 ~ DN150

     Accuracy

    ±0.5%; optional ±0.2%

    Converter housing

    All-stainless-steel housing

    Liner material

    PFA

    Electrode material

    316L; Hastelloy B; Hastelloy C; Platinum; Tantalum; Titanium

    Seal Materials

    EPDM,FKM

    Hygienic connections

    Tri-Clamp and other sanitary clamp connections, weld, or thread

    Wetted surface roughness

    Ra ≤0.4 µm

    Process temperature

    -40℃~150℃

    Ambient temperature

    -20℃~60℃, with display
    -40℃~60℃, without display

    Wiring options

    M12 4-pin connectors or internal terminal wiring

    Measuring range

    0.1m/s~10m/s

    Minimum conductivity

    ≥5μS/cm

    Output signal

    4~20mA / Frequency / Pulse

    Communication

    Modbus RS485

    Certification

    3-A, CE

    Product Feature

    Aimag H 3-A certified sanitary design with all-stainless-steel construction
    Aimag H high-temperature PFA liner suitable for CIP and SIP cleaning cycles

    3-A Certified Sanitary Design

    3-A certified hygienic construction supports beverage, dairy, wine, and other food-grade production lines.

    High-Temperature PFA Liner

    The PFA liner supports process temperatures up to 150°C and repeated CIP and SIP cleaning cycles.

    Smaller and Lighter Converter

    The converter is approximately 30–50% the volume of conventional designs, reducing the overall meter weight while giving the instrument a more compact and refined appearance.

    All-Stainless-Steel Housing

    The all-stainless-steel construction provides a clean, refined appearance and is well suited to hygienic applications in food and beverage processing.

    Ra ≤0.4 µm Wetted Surfaces

    Wetted surfaces with a roughness of Ra ≤0.4 µm exceed typical 3-A surface-finish requirements, helping reduce residue buildup and support effective cleaning.

    Optional M12 Plug-In Connections

    Optional M12 4-pin connectors enable wiring and cable replacement without opening the converter enclosure.

    Supported Conditions and Functions

    Electromagnetic flow meter with ambient temperature range from -40°C to 85°C for outdoor industrial applications

    Supports stable operation in outdoor and industrial environments.

    Electromagnetic flow meter with EMC certification for stable operation in industrial electromagnetic environments

    Supports reliable operation in industrial environments with electromagnetic interference.

    Typical Applications

    • Beverage production, blending, and filling lines
    • Milk and dairy processing
    • Brewing and wine production
    • Pharmaceutical and other hygienic process systems
    • CIP/SIP supply, return, and circulation lines
    • Sanitary process water and cleaning-water systems
    • OEM skids and packaged processing equipment
    ARTang flow meter installed alongside Endress+Hauser instruments in an industrial process line

    ARTang and Endress+Hauser instruments operating on the same CIP process line.

    ARTang magnetic flow meter and Endress+Hauser flow meter operating in the same stainless steel process piping system

    ARTang electromagnetic flow meter in a shared process application.

    ARTang flow meter installed with Endress+Hauser instruments in a process automation application site

    ARTang flow meter in a CIP line with Endress+Hauser instruments.

    ARTang flow meter working with KROHNE equipment in an industrial flow measurement application

    ARTang and KROHNE instruments used in the same blending water process.

    Sanitary electromagnetic flow meters installed in beverage production line

    Dairy Production

    Sanitary electromagnetic flow meter installed in a milk and dairy processing plant

    CIP Cleaning System

    Sanitary electromagnetic flow meter used in a food and beverage production line

    Beverage

    Sanitary electromagnetic flow meter installed in a brewery process pipeline

    Beer

    flowmeter calibration equipment

    Each electromagnetic flow meter is calibrated before shipment to verify its measurement accuracy and stability. Our calibration process includes standard meter method and weighing method calibration to ensure reliable performance under real working conditions.

    Flow meter calibration testing system for factory accuracy verification before delivery

    Standard Meter Method Calibration

    Accuracy is verified by comparing the electromagnetic flow meter with a certified standard meter.

    Flow meter calibration testing system for factory accuracy verification before delivery

    Weighing Method Calibration

    Flow accuracy is checked by measuring the collected liquid weight over a set time.

    Related Articles

    Factory Strength & Quality Assurance

    ARTang supports industrial measurement projects with in-house production, strict calibration, certified quality control, and global exhibition experience.

    Factory Production

    In-house production and assembly for stable product quality and reliable delivery.

    Worker operating production equipment for instruments and meters

    CNC Machining Equipment

    ARTang worker operating production instruments and equipment

    Product Assembly

    CNC Machining

    Welding Process

    artang warehouse

    warehouse

    Technical Support Department

    Certified Quality

    Product certificates and quality control systems support reliable industrial measurement applications.

    CE certificate for electromagnetic flowmeter

    CE

    ISO 9001 quality management system certificate

    ISO

    3-A sanitary certificate for electromagnetic flowmeter

    3-A

    NEPSI explosion protection certificate for integral magnetic flowmeter

    NEPSI

    Exhibition Experience

    ARTang meets customers and distributors at industry exhibitions to better understand project needs and market requirements.

    ARTang at an industrial instrumentation exhibition, showcasing flow meters and pressure transmitters for process automation applications