AED28 Double Flanges Differential Pressure Transmitter

Measurement Range: 0-40KPa……0-3MPa

Accuracy: ± 0.2%

Output: 4~20mA, 4~20mA+HART, MODBUS RS485

Protection Level: IP65/IP67

Explosion -Proof: NEPSI EXDB IIC T6 GB

    Product Description

    Dimension drawing of remote seal differential pressure transmitter with dual flange diaphragms

    Specification

    Parameter

    Specification

    Model number

    AED28

    Accuracy

    ±0.2%

    Output signal

    4-20mA, 4-20mA+HART, ModBus RS485

    Power supply

    10~32VDC

    Overload presure limit(OPL)

    Single High Side Max 16 Mpa

    Process temperature

    -40℃ ~ 315℃ (depending on the medium)

    Ambient Temperature

    -40℃ ~ 85℃ or -20℃ ~ 70℃(with LCD)

    Measuring range

    0-3MPa

    Response time

    0.25s

    Power supply influence

    ≤±0.005%/URL/V

    Protection grade

    IP65 (factory default); IP67 (optional)

    Explosion-proof grade

    NEPSI Ex db IIC T6 Gb

    Explosion -proof

    NEPSI EXDB IIC T6 GB

    Housing material

    Cast aluminum alloy; SUS304

    Diaphragm material

    SUS316L; Hastelloy C; Tantalum; SUS316L gold plated; SUS316L PTFE coating

    Features

    1. High accuracy: The pressure transmitter can perform high-accuracy measurements within the measurement range of 0-3MPa.

    2. Standard accuracy: ±0.2%; no linearity adjustment is required when the positive and negative zero points migrate;

    3. Excellent environmental adaptability: The advanced floating diaphragm box protects the sensor from the influence of temperature and overpressure, and controls the comprehensive measurement error on site to a minimum.

    4. Excellent operability and easy usability: All ranges meet explosion-proof requirements; stainless steel transmission housing is available; various corrosion-resistant materials are available;

    5. HART communication protocol, FOUNDATION fieldbus, and PROFIBUS bus are used for communication.

    6. It can accurately measure pressure and convert it into a DC4~20mA output signal. It uses a silicon microcapacitive sensor and a microprocessor made by micromachining technology.

    7. Features and functions: small, lightweight, excellent environmental adaptability, suitable for all fields.

    Application fields of double flange differential pressure transmitters

    Application fields: Double flange differential pressure transmitters are widely used in various industrial fields. Here are some common application scenarios:

    1. Petrochemical: In petrochemical processes, double flange differential pressure transmitters are used to measure the pressure difference in fluid media to control flow, monitor pipeline blockage, detect leaks, etc.

    2. Power engineering: In power engineering, double flange differential pressure transmitters are used to measure the pressure difference in boilers to ensure the normal operation of boilers and improve thermal efficiency.

    3. Automation control: Double flange differential pressure transmitters play an important role in automation control systems. It can convert pressure differences into electrical signals for controlling and adjusting the working status of the system, such as automated process control, liquid level control, etc.

    Installation position of double flange differential pressure transmitter

    Liquid level measuremen

    • Open tank liquid level measurement: Install the instrument below the lowest measurement point, and connect the negative pressure side directly to the atmospheric pressure.

    • Closed tank liquid level measurement: Install the instrument below the lowest measurement point, connect the negative pressure side through the pressure pipe, and ensure that the connection point on the pressure pipe is always higher than the highest liquid level.

    Pressure measurement

    • Gas measurement

    When measuring gas, the pressure port should be opened on the side or top of the process pipeline, and the transmitter should be installed above the process pipeline so that the accumulated liquid can easily flow into the process pipeline. For transmitters with a relief valve in the pressure chamber, the relief port of the relief valve should be placed downward. In order to discharge the accumulated liquid in the measured medium.

    • Liquid measurement

    When measuring liquid, the pressure port should be opened on the side of the process pipeline to avoid slag deposition. At the same time, the transmitter should be installed below the pressure port so that bubbles can be discharged into the process pipeline. For transmitters with a relief valve in the pressure chamber, the relief port of the relief valve should be placed upward to discharge the gas in the measured medium.

    • Steam measurement

    When measuring steam, the pressure tapping port should be opened on the side of the process pipeline, and the transmitter should be installed below the pressure tapping port so that the condensate can be filled in the pressure pipe.

    Installation diagram of double flange differential pressure transmitter for tank level measurement

    Pressure Calibration Equipment

    At ARTang, every pressure transmitter is calibrated through automated multi-point pressure control systems. Full-range verification ensures temperature stability and signal integrity for traceable accuracy in industrial applications.

    Pressure Calibration System

    High-Precision Multi-Range Pressure Calibration

    Electrical Signal Verification

    High and Low Temperature Test Chamber

    Factory Strength & Quality Assurance

    ARTang supports industrial measurement projects with in-house production, strict calibration, certified quality control, and global exhibition experience.

    Factory Production

    In-house production and assembly for stable product quality and reliable delivery.

    Worker operating production equipment for instruments and meters

    CNC Machining Equipment

    ARTang worker operating production instruments and equipment

    Product Assembly

    CNC Machining

    Welding Process

    artang warehouse

    warehouse

    Technical Support Department

    Certified Quality

    Product certificates and quality control systems support reliable industrial measurement applications.

    CE certificate for electromagnetic flowmeter

    CE

    ISO 9001 quality management system certificate

    ISO

    3-A sanitary certificate for electromagnetic flowmeter

    3-A

    NEPSI explosion protection certificate for integral magnetic flowmeter

    NEPSI

    Exhibition Experience

    ARTang meets customers and distributors at industry exhibitions to better understand project needs and market requirements.

    ARTang at an industrial instrumentation exhibition, showcasing flow meters and pressure transmitters for process automation applications