ACT115 Conductivity Transmitter with 4–20 mA Output

The ARTang ACT115 is a panel-mount conductivity transmitter for water treatment, process-water monitoring and OEM equipment. It combines a local LCD display, 4–20 mA output and a high-limit relay for measurement indication, remote monitoring and threshold-based control.

Electrode Cell Constants: 0.1, 1.0 or 10.0 cm⁻¹

Analog Output: 4–20 mA

Control Output: High-limit relay

Temperature Compensation: Automatic

Panel Cutout: 45 × 92 mm (H × W)

Power Supply Options: 110 V AC, 220 V AC or 24 V DC

    Product Description

    The ACT115 conductivity transmitter connects to a compatible conductivity electrode to provide continuous measurement of water or compatible aqueous process liquids. The 4–20 mA signal sends the measurement to a PLC, recorder or supervisory system. A high-limit relay provides an output for an external alarm or control circuit when conductivity reaches the configured threshold.

    Technical Specifications

    Parameter

    Specification

    Model

    ACT115

    Product Type

    Panel-mount conductivity transmitter

    Accuracy

    1.5% FS

    Accuracy

    1.5% FS

    Temperature Compensation

    Automatic

    Process Temperature

    0–100°C, subject to the selected electrode’s rating

    Supported Electrode Cell Constants

    0.1, 1.0 and 10.0 cm⁻

    Analog Output

    4–20 mA

    Control Output

    High-limit relay

    Power Supply Options

    110 V AC ±10%, 50/60 Hz; 220 V AC ±10%, 50/60 Hz; or 24 V DC

    Ambient Temperature

    0–50°C

    Ambient Temperature

    0–50°C

    Housing Dimensions

    48 × 96 × 100 mm (H × W × D)

    Panel Cutout

    45 × 92 mm (H × W)

    Installation

    Panel mount

    Measurement Ranges and Electrode Selection

    Available Measurement Range

    Electrode Cell Constant

    0–20 μS/cm

    0.1 cm⁻

    0 ~ 20/200/2000 μS/cm

    1.0 cm⁻¹

    0–20 mS/cm

    1.0 cm⁻¹

    0–200 mS/cm

    10.0 cm⁻¹

    Product Features and Advantages

    Conductivity transmitter with 4–20 mA output for remote monitoring and high-limit relay for alarm and control
    Conductivity transmitter with automatic temperature compensation and support for 0.1, 1.0 and 10.0 cm⁻¹ cell constants

    4–20 mA Output for Remote Monitoring

    High-Limit Relay for Alarm and Control

    Automatic Temperature Compensation

    Support for Three Electrode Cell Constants

    Support for 0.1, 1.0 and 10.0 cm⁻¹ cell constants allows the instrument to be paired with electrodes for different conductivity ranges.

    Compact Panel Installation

    Typical Applications

    Water Treatment and Reverse Osmosis Equipment

    Monitor conductivity at selected feed-water, treated-water or permeate measurement points.

    Industrial Process and Circulating Water

    Provide local conductivity indication and remote measurement signals for process-water supplies, circulating-water systems and cooling-water equipment.

    Industrial Wastewater

    Monitor conductivity changes in compatible wastewater streams.

    OEM Equipment and Control Panels

    Integrate conductivity measurement into water-treatment skids, rinse-water systems and liquid-processing equipment.

    Frequently Asked Questions

    Can the ACT115 connect to a PLC?

    Yes. Its 4–20 mA output can connect to a compatible PLC analog input. Ensure the electrical connection and measurement scaling match the PLC input configuration.

    Does it provide both high- and low-limit relays?

    The specified control output is a high-limit relay. If your application requires additional alarm or control outputs, include those requirements in your inquiry.

    Can it use a sensor rated up to 350 mS/cm?

    A sensor’s range does not increase the transmitter’s range. The ACT115’s listed maximum conductivity range is 0–200 mS/cm with a 10.0 cm⁻¹ electrode. Sensor wiring and temperature element compatibility must also be confirmed.

    Discuss Your Conductivity Measurement Requirements

    Send ARTang your expected conductivity range, liquid conditions, power supply and control requirements. If you already have an electrode, include its model, cell constant and temperature element.

    Our team can help review the ACT115 measurement range, electrode pairing and system connections for your project.

      Factory Strength & Quality Assurance

      ARTang supports industrial measurement projects with in-house production, strict calibration, certified quality control, and global exhibition experience.

      Factory Production

      In-house production and assembly for stable product quality and reliable delivery.

      Worker operating production equipment for instruments and meters

      CNC Machining Equipment

      ARTang worker operating production instruments and equipment

      Product Assembly

      CNC Machining

      Welding Process

      artang warehouse

      warehouse

      Technical Support Department

      Certified Quality

      Product certificates and quality control systems support reliable industrial measurement applications.

      CE certificate for electromagnetic flowmeter

      CE

      ISO 9001 quality management system certificate

      ISO

      3-A sanitary certificate for electromagnetic flowmeter

      3-A

      NEPSI explosion protection certificate for integral magnetic flowmeter

      NEPSI

      Exhibition Experience

      ARTang meets customers and distributors at industry exhibitions to better understand project needs and market requirements.

      ARTang at an industrial instrumentation exhibition, showcasing flow meters and pressure transmitters for process automation applications