Electromagnetic Flowmeter
Electromagnetic Flowmeter Manufacturer & Supplier for Industrial Flow Measurement
ARTang is a professional electromagnetic flowmeter manufacturer and supplier in China, specializing in the R&D and manufacturing of magnetic flow meters for industrial conductive liquid measurement.
With CE, 3-A Sanitary, and explosion-proof certifications, we provide standard and customized flow measurement solutions with selectable liners, electrode materials, and process connections. Our electromagnetic flowmeters are widely used in water supply, wastewater treatment, food and beverage, mining, metallurgy, chemical processing, and other industrial applications.
Products
Flowmeter
Electromagnetic Flowmeter Applications
Water & Wastewater
Suitable for raw water, municipal water supply, circulating water, municipal and industrial wastewater, and return activated sludge (RAS). Selection should consider pipe size, flow range, conductivity, temperature, pressure, solids content, abrasion, corrosion, grounding and material compatibility.
Recommended: Standard Electromagnetic Flowmeter
Food & Beverage
The food and beverage industry requires hygienic flow measurement, reliable accuracy, and easy-to-clean instrumentation. ARTang sanitary electromagnetic flow meters are 3-A certified and feature an all-stainless-steel housing, making them well suited for production, batching, filling, blending, and CIP and SIP cleaning lines.
Recommended: Sanitary Electromagnetic Flowmeter
Pulp & Slurry
Fibrous pulp, sludge, mining slurry and tailings may cause signal noise, electrode coating and liner wear during flow measurement.
Dual-frequency excitation and suitable liner and electrode materials help improve measurement stability.
Recommended: Slurry Electromagnetic Flowmeter
Chemical Processing
Strong acids, alkalis, chemical reagents, and high-temperature or corrosive processes require compatible liners, electrodes, and suitable electromagnetic flowmeter configurations. Selection should consider the medium, temperature, pressure, and hazardous-area certification requirements to ensure reliable measurement and long-term stability.
Recommended: Chemical Electromagnetic Flowmeter
HVAC & Energy
Electromagnetic BTU Meter calculates energy consumption by combining flow measurement with the temperature difference between the supply and return pipelines. It is used in chilled-water and hot-water systems, HVAC plants, district heating and cooling networks, and commercial or industrial energy monitoring.
Recommended: Electromagnetic BTU Meter
Large Pipelines & Retrofits
Suitable for large-diameter pipelines, retrofit projects and sites where installing a full-bore meter is difficult or costly. Insertion electromagnetic flowmeters reduce pipeline modification and installation work, while fewer models can cover a wide range of pipe sizes and simplify spare-parts management.
Recommended: Insertion Electromagnetic Flowmeter
How Electromagnetic Flowmeters Work
Measurement Principle
Electromagnetic flowmeters measure conductive liquids based on Faraday’s law. As the liquid flows through a magnetic field, electrodes detect an induced voltage proportional to the flow velocity. The transmitter processes this signal and calculates the volumetric flow rate based on the known cross-sectional area of the measuring tube.
With no moving parts or obstruction in the measuring tube, magnetic flowmeters create no significant pressure loss and require little mechanical maintenance.
Measurement Requirements
Reliable measurement requires sufficient liquid conductivity, a completely filled pipe and stable grounding. Excessive air bubbles, unsuitable flow velocity or incompatible liner and electrode materials may affect measurement performance.
Application Range
Suitable for conductive liquids such as water, wastewater, slurry, pulp, acids, alkalis and conductive food or beverage liquids.
How to Select the Right Electromagnetic Flowmeter
As an electromagnetic flowmeter supplier, ARTang recommends selecting the right model based on fluid properties, process conditions, material compatibility, installation requirements, and signal integration to ensure accurate and reliable flow measurement before quotation.
Process Conditions & Fluid Properties
Start by confirming the measured medium, process temperature, operating pressure, flow rate range, and pipe size to determine the basic electromagnetic flowmeter configuration for your application.
Fluid Conductivity Requirements
Fluid conductivity is essential for magnetic flow measurement. Standard electromagnetic flowmeters are suitable for media above 5 µS/cm, while low-conductivity liquids from 0.8–5 µS/cm may require ARTang pure water magnetic flowmeters.
Liner and Electrode Material Selection
Liner and electrode materials should be selected according to fluid corrosiveness, abrasion, temperature, and pressure.
Nominal Diameter and Connection
The flowmeter size and connection type should match the pipeline size and installation conditions.
Power Supply and Output Signals
Power supply and output signals should be confirmed according to your control system requirements.
Available Configuration Options
|
Configuration |
Available Options |
|---|---|
|
Nominal Diameter |
DN6~DN2200 |
|
Accuracy |
±0.5%, ±0.2% optional |
|
Liner Materials |
PTFE, PFA, neoprene, polyurethane, FEP |
|
Electrode Materials |
316L, Hastelloy B, Hastelloy C, titanium, tantalum, platinum |
|
Process Connections |
Flanged, tri-clamp, wafer, threaded |
|
Converter Mounting |
Compact, remote |
|
Power Supply |
220 VAC, 24 VDC, battery |
|
Outputs & Communication |
4–20 mA, pulse, frequency, alarm, RS485, HART |
Key Features of Electromagnetic Flowmeters
Wide Range of Applications
ARTang electromagnetic flowmeters are compatible with a broad variety of media, including water, wastewater, dairy products, beverages, solid-containing liquids, pulp, low-conductivity pure water and more.
Long-term Stable Operation
Benefiting from continuous investment in R&D and manufacturing, ARTang electromagnetic flowmeters maintain long-term reliable and stable operation in industrial environments. This durability significantly reduces maintenance costs for our customers.
Comprehensive Certifications
We hold a complete portfolio of certifications and third-party test reports, including CE, 3A Sanitary, Explosion-proof, Accuracy Class, Pressure Rating, and Ingress Protection (IP) ratings. These accreditations guarantee the superior quality of our products.
Manufacturing, Calibration & Quality Control
ARTang controls key stages from sensor production and assembly to testing, flow calibration and final inspection. Each electromagnetic flowmeter is manufactured and checked according to the confirmed model, materials and project requirements.
Production & Assembly
Measuring tubes, liners, electrodes, process connections and converters are manufactured, prepared and assembled according to the confirmed product configuration
Pressure & Functional Testing
Leak tightness, pressure resistance, display operation, power supply, output signals and communication functions are tested according to the product model and configuration.
Flow Calibration
Measurement accuracy is verified on a flow calibration system at multiple flow points. Each flowmeter is supplied with an individual calibration report, enclosed in the packaging and shipped together with the instrument.
Final Inspection & Packing
Product configuration, appearance, nameplate, accessories, documents and protective packing are checked before shipment.
Why Choose ARTang for Electromagnetic Flowmeters
Factory & R&D
With our own factory and R&D team, ARTang provides stable, reliable, and adaptable electromagnetic flowmeter solutions. We have developed specialized models for pure water, food and beverage, pulp and paper, and other industrial applications.
Certified Quality
ARTang products are supported by CE, ISO, 3-A sanitary, NEPSI explosion-proof, EAC and other certifications. We can also provide third-party test reports for accuracy grade, pressure resistance, protection rating, and material compliance when required.
Technical Support
Our technical support team assists customers with both pre-sales product selection and after-sales service. Whether you need help with model selection, process conditions, installation, or troubleshooting, we respond quickly with practical and professional guidance.
Core Certifications
CE – Electromagnetic Flow Meter
3-A – Sanitary Flow Meter
ISO 9001 – Quality Management
NEPSI Explosion Protection – Integral Flow Meter
Technical documents for electromagnetic flowmeters are available in our Download Center.
FAQ About Electromagnetic Flowmeters
An electromagnetic flowmeter can measure conductive liquids such as water, wastewater, slurry, acid, alkali, chemical liquids, and some food or beverage liquids. It is not suitable for non-conductive liquids such as oil, gas, steam, or pure hydrocarbons.
No. Electromagnetic flowmeters are not suitable for non-conductive liquids such as oil, gas, steam, or pure hydrocarbons.
The lining material should be selected according to the liquid’s corrosion, abrasion, temperature, and hygiene requirements. Common options include PTFE, PFA, rubber, and polyurethane. For corrosive liquids, PTFE or PFA is often considered. For abrasive slurry, wear-resistant lining may be required.
An integrated electromagnetic flowmeter combines the sensor and transmitter in one unit, which is suitable for standard installation. A remote type separates the transmitter from the sensor and is better for high temperature, vibration, flooded, underground, or hard-to-access locations.
Yes. ARTang supports customized electromagnetic flowmeters with different sizes, materials, connections, transmitter types, signal outputs, and installation options.
Need Help Choosing an Electromagnetic Flowmeter?
Send us your application details, including medium, pipe size, flow range, pressure, temperature, and output requirements. ARTang will help you select a suitable electromagnetic flowmeter for your project.