Flowmeter manufacturer

Full bore electromagnetic flowmeter

The full bore electromagnetic flowmeter is used to measure the volume flow of conductive liquids with conductivity greater than 5μS/cm , such as acids, alkalis, salts and other highly corrosive liquids.
Quantity:

Introduction

The Full bore electromagnetic flowmeter is based on Faraday's law of electromagnetic induction. The inductive voltage is generated when a conductor cuts the magnetic line and move in a magnetic field.The electromagnetic flowmeter generates a constant alternating magnetic field by switching direct current I with alternating polar transformations.The magnetic field direction is perpendicular to the direction of the flow .When magnetic flow meter measures the flow rate,the medium flows through the magnetic field.the moving medium is equivalent to the moving conductor,inducts an electric force Ue ,which is proportional to the velocity of the medium, as shown in the followed figure.

3-3

Measurement figure 1

Ue = B ∙ L ∙ v


B: Magnetic induction strength
L: Electrode spacing
v: Media Flow Rate

The electromagnetic flowmeter detects the inductive electric force through two measuring electrodes and transmits it to the converter for processing,based on measuring pipe cross-sectional area A ,the volume flow Q of the fluid can be calculated .

Specification

Sensor model Aimag C
Application Chemical process
Nominal diameter
DN15-DN600
Electrode material Stainless steel ,Hastelloy B,Hastelloy C,Titanium,Tantalum

Lining material and process 

 temperature

Neoprene:0~80℃       Polyurethane: -20~65℃

PTFE:-40~130℃(Compact type)          PTFE:-40~180℃(Split type)

Process connection Flange: GB,ANSI, DIN, JIS
Process pressure PN 10~40, CL150/300,JIS10K/20K
Accuracy class ±0.5%/0.2%
Output signal 4-20mA frequency/pulse
Communication HART ,Modbus RS485,PROFIBUSDP
Explosion-proof certification CQEX
Protection level IP67(optional IP68)


Features

  • Theoretically, it is completely unaffected by pressure, density, temperature and viscosity

  • High measurement accuracy, up to 0.5%, 0.2% optional

  • No shut-off parts in the measuring tube, no additional pressure loss

  • Wide measuring range, nominal diameter DN15~DN3000

  • No moving parts in the measuring tube, maintenance-free

  • Abundant types of linings and electrodes can meet the requirements of corrosion resistance and wear resistance


Introduction

1-1

Calibration-800