knowledge
How to Select an Electromagnetic Flow Meter for Slurry Applications
Magnetic flow meters are commonly used for conductive slurries because they have no moving parts or internal obstructions. However, suspended solids can accelerate liner wear, build up on the electrodes and interfere with measurement stability.
The key selection question is not simply whether the liquid contains solids. It is whether abrasion, corrosion or slurry-related signal interference requires a specialized meter configuration.
To select the right meter, focus on three questions:
- How abrasive are the solids?
- How corrosive is the liquid phase?
- Will the particles or fibers interfere with the measuring signal?

Suspended solids flow measurement

Slurry flow measurement.
Identify the Slurry Characteristics
Before selecting the meter, evaluate both the solids and the continuous liquid phase.
Important information includes:
- Solids concentration by weight or volume
- Average and maximum particle size
- Particle hardness and shape
- Presence of fibers
- Settling or adhesion tendency
- Liquid-phase composition
- Conductivity, temperature and pressure
Solids concentration alone does not determine whether a general-purpose or slurry-specific meter is required. Soft wastewater sludge, abrasive mineral slurry and fibrous paper pulp may have similar solids concentrations but affect wear and signal stability differently.
The continuous liquid phase must also meet the minimum conductivity requirement of the selected magnetic flow meter.
Flow velocity should also be considered, especially for settling or abrasive slurries. Low velocity may increase solids settling, while excessive velocity can accelerate liner and electrode wear.
Standard or Slurry-Specific Electromagnetic Flow Meter?
The choice between a general-purpose and slurry-specific electromagnetic flow meter depends mainly on how the solids affect wear and measurement stability.
When a General-Purpose Meter May Be Sufficient
A general-purpose electromagnetic flow meter may be suitable when:
- The solids concentration is relatively low or moderate
- The particles are small or soft
- The mixture remains reasonably uniform
- The solids do not cause serious signal fluctuation
- Corrosion and wear can be managed through suitable wetted materials
Possible applications include general wastewater, treated sewage and selected industrial liquids containing fine suspended solids.
In these conditions, selecting the correct liner and electrode materials may be more important than choosing a specialized slurry meter. Using a slurry-specific model may increase cost without providing a meaningful improvement in measurement performance.
When a Slurry-Specific Meter Is More Suitable
A slurry-specific electromagnetic flow meter should be considered when particles, fibers or changing solids distribution cause persistent interference in the measuring signal.
This may occur in:
- Mineral and mining slurry
- Tailings slurry
- Concentrated sludge
- High-consistency pulp
- Fibrous process liquids
- Media containing dense, hard or irregular particles
When solids pass across the electrodes, they can generate short-duration electrical interference. The displayed flow rate may therefore fluctuate even when the actual flow remains relatively stable.
A slurry-specific meter uses sensor and signal-processing methods designed to obtain a more stable flow signal under these conditions. The main reason to choose a slurry model is therefore not simply the presence of solids, but the effect those solids have on measurement stability.
There is no universal solids-percentage threshold that applies to every slurry. Particle size, hardness, fiber content, settling behavior and actual process performance must also be considered.
Select the Liner and Electrode Materials
The liner and electrodes affect corrosion resistance, wear resistance and service life. Their selection should be evaluated separately from the meter’s signal-processing capability.
Liner Selection
Select the liner according to abrasion, chemical compatibility and process temperature.
|
Slurry condition |
Main priority |
Commonly considered liner |
|---|---|---|
|
General wastewater with suspended solids |
General durability |
Neoprene rubber |
|
Abrasive mineral or sand slurry |
Abrasion resistance |
Polyurethane |
|
Corrosive chemical slurry |
Chemical resistance |
PTFE or PFA |
|
Combined abrasion and corrosion |
Balance both requirements |
Application-specific evaluation |
Polyurethane is commonly considered for abrasive mineral or sand slurry, while PTFE and PFA are more frequently used when chemical resistance is the main requirement.
The most chemically resistant liner is not necessarily the most wear-resistant. Final selection should be checked against the actual particle characteristics, chemical concentration and operating temperature.
Electrode Selection
Electrode material is selected mainly according to the chemical properties of the slurry’s liquid phase, while abrasive solids may also require greater wear resistance. Common options include 316L stainless steel, Hastelloy, titanium, tantalum and platinum-based materials. For highly abrasive slurries containing hard particles, tungsten carbide or wear-resistant electrode configurations may also be considered.
Electrode selection should also consider particle impact, surface adhesion and cleaning requirements, because deposits covering the electrode surface may affect signal stability even when the material is chemically compatible.
For additional material compatibility information, see the Electromagnetic Flow Meter Liner and Electrode Selection Guide.
Check the Required Signal-Processing Capability
Slurries can generate electrical noise through particle or fiber interaction with the electrodes, uneven solids distribution and changes at the electrode surface. This noise may appear as spikes or unstable flow readings even when the actual flow is relatively steady.
For demanding slurry applications, consider:
- Optimized excitation frequency.Higher or specially selected excitation frequencies can improve resistance to low-frequency slurry noise.
- Slurry-oriented signal processing.The transmitter should suppress particle- or fiber-related fluctuations without excessively filtering real flow changes.
- Stable zero performance.Good noise resistance should not come at the expense of zero stability, especially at low flow.
A slurry-specific electromagnetic flow meter should improve signal extraction and noise resistance rather than simply smoothing unstable readings by increasing the damping time.
Before attributing unstable readings to slurry noise, confirm that the pipe is full and the meter is correctly grounded. Entrained air, electrode coating or poor installation can also cause signal instability.
For general installation requirements, see the Electromagnetic Flow Meter Installation Guide.
Information Required for Slurry Flow Meter Selection
Provide the following information when requesting a flow meter recommendation:
- Slurry name, liquid-phase composition.
- Solids concentration, by weight or volume
- Particle size, hardness, shape and presence of fibers
- Settling, adhesion or coating tendency
- Minimum, normal and maximum flow rate, plus pipe size
- Process temperature and pressure
- Existing measurement problems, if applicable
- Installation and signal-output requirements
Complete process information helps determine whether a general-purpose meter is sufficient and which liner, electrode and transmitter configuration is appropriate.
Which ARTang Model Is Suitable for Your Slurry Application?
ARTang provides general-purpose and slurry-specific electromagnetic flow meters for conductive liquids containing suspended solids.
The Aimag-A electromagnetic flow meter is a high-quality general-purpose model suitable for a wide range of conductive liquids, including wastewater and media with moderate suspended solids. It offers multiple liner and electrode options to match different abrasion and corrosion conditions.
For more demanding slurry applications, the Aimag-S slurry electromagnetic flow meter uses a unique sensor design, dual-frequency excitation and signal oversampling technology to improve resistance to interference caused by solid particles and fibers and provide a more stable flow signal.
Both models are manufactured under ARTang’s quality-control process and calibrated at three real-flow points before delivery. The choice between Aimag-A and Aimag-S should therefore be based on slurry severity and signal conditions rather than simply on the presence of suspended solids.

Pulp and paper processes

Aimag-S slurry flow meter in a pulp and paper application
Conclusion
Selecting an electromagnetic flow meter for slurry requires separate consideration of abrasion, chemical compatibility and signal interference.
A properly configured general-purpose meter may be sufficient when solids are limited and the measurement remains stable. When dense particles or fibers produce persistent signal interference, a slurry-specific electromagnetic flow meter is more appropriate.
Need Help Choosing the Right Electromagnetic Flowmeter?
ARTang can help evaluate your medium, site conditions, and configuration requirements, then recommend a suitable electromagnetic flowmeter solution.
Related posts
pH Electrode Junction Types: Differences and Selection Guide
Electromagnetic Flow Meter for Corrosive Liquids: How to Choose Liner and Electrode Materials
ARTang Magnetic Flow Meters in Drinking Water Treatment Plants
How to Install an Industrial pH Sensor Correctly
Why Is My pH Reading Unstable? 7 Common Causes and Solutions
How to Choose a pH Sensor for Wastewater Treatment
How to Select an Electromagnetic Flow Meter for Slurry Applications
How to Clean a pH Electrode: Methods for Different Contaminants
How to Calibrate a pH Meter and Electrode: Step-by-Step Guide
ARTang Sanitary Electromagnetic Flow Meter in a Nongfu Spring Beverage Sterilization System
What Is a BTU Meter? How It Works, Types & Applications
Electromagnetic vs Ultrasonic Flow Meter: Which One Should You Choose?
Contents
Toggle